Pneumatic hoses:
Should be pressurized for proper inspection
Must be inspected with a borescope
Are manually cleaned using a mild acetic solution
Should be cleaned in the ultrasonic cleaner
Oops!
Okay!
Dark areas on the lens of an endoscope are:
Damaged light fibers
Debris
Light-emitting diode (LED) optics
LED bulbs
Oops!
Okay!
Used in open heart surgery
dermatome/dermabrader
dental drill
sternal saw
cebatome
Oops!
Okay!
Dental drills are used to remove cement.
False
True
Oops!
Okay!
Type of powered surgical instrument used for open heart surgery
pneumatic
electric
sternal saw
battery
Oops!
Okay!
Type of powered surgical instrument usually used for large bone surgery
battery
pneumatic
sternal saw
electric
Oops!
Okay!
Which of the following steps occurs first when processing flexible endoscopes?
Leak testing
High-level disinfection/sterilization
Drying
Manual cleaning
Oops!
Okay!
Arthroscopy instruments are used during:
Laparoscopic surgery
Joint surgery
Robotic surgery
All the above
Oops!
Okay!
The purpose of a decontamination battery is to protect powered surgical instruments from fluid invasion.
True
False
Oops!
Okay!
Which of the following is an advantage of minimally invasive surgery (MIS)?
Cost savings for the patient
All procedures can be done in a same-day surgery center
Fewer instruments are used
Shorter recovery times
Oops!
Okay!
Powered surgical instrument batteries should be charged per the manufacturers' instructions for use (IFU):
In the decontamination area
In the OR
During PM inspections
Before sterilization
Oops!
Okay!
Loaned instrument trays that are received sterile from do not need to be decontaminated.
True
False
Oops!
Okay!
Semi-rigid endoscopes:
Are electrically powered
Do not have fiber optics
Should be leak tested prior to cleaning
Are used during urological procedures
Oops!
Okay!
Used to remove cement
sternal saw
cebatome
dental drill
dermatome/dermabrader
Oops!
Okay!
A problem with electric surgical instruments is condensation entering the device when the seals wear out.
True
False
Oops!
Okay!
Robotic instruments:
May have exposed cables
Must be containerized for sterilization
Are processed the same as laparoscopic instruments
Require extensive preventive maintenance (PM)
Oops!
Okay!
Which of the following statements about endoscopes is true?
Ultrasonic cleaning is the process of choice for endoscopes
All endoscopes should be steam sterilized
Flexible endoscopes are not easily damaged
Flexible endoscopes are time-consuming to clean
Oops!
Okay!
When returning loaned items to the vendor:
All items should be completely assembled, tested and sterile
Trays should be terminally sterilized
Trays are returned immediately after point-of use treatment
All items should be cleaned and decontaminated
Oops!
Okay!
3. Type of powered surgical instrument used for dental surgery
battery
electric
operative
sternal saw
Oops!
Okay!
Powered surgical instrument attachments:
Can all be mechanically cleaned
Should be sterilized while still attached to the handpiece
Are interchangeable with all types of drills
Can be peel packaged for if approved by the manufacturer
Oops!
Okay!
Pneumatic cords are a cleaning concern because:
The cord does not detach from the device
Of their length
They are dark in color, so soil is difficult to see
The electrical plug is very delicate
Oops!
Okay!
Electronic testing of laparoscopic insulation should be done:
At the factory or onsite repair unit
In the decontamination area prior to cleaning
In the Operating Room (OR) at the end of the procedure
In the clean assembly area prior to set assembly
Oops!
Okay!
Type of powered surgical instrument powered by compressed air or gas
sternal saw
pneumatic
operative
electric
Oops!
Okay!
Endoscopic cameras:
Should be inspected for cuts, nicks or damage to the cabl
Should be cleaned using a medium-bristled brush
Should be inspected using a borescope
Are only used with non-operative endoscopes
Oops!
Okay!
Used to repair and reconstruct teeth and jawbones
dental drill
cebatome
dermatome/dermabrader
sternal saw
Oops!
Okay!
Type of flexible endoscope that allows physicians to perform some surgery
pneumatic
electric
sternal saw
operative
Oops!
Okay!
Information regarding cleaning processes for endoscopes should be provided by the:
Society of Gastroenterology Nurses and Associates (SGNA)
Association Professionals Infection Control (APIC)
Instrument manufacturer
Operating Room (OR) staff
Oops!
Okay!
Which of the following statements about endoscopes is true?
All endoscopes should be steam sterilized
Ultrasonic cleaning is the process of choice for endoscopes
Flexible endoscopes are not easily damaged
Flexible endoscopes are time-consuming to clean
Oops!
Okay!
The first step when inspecting the insulation of a laparoscopic instrument is to:
Try to slide the insulation back
Visually check the instrument's shaft
Check the metal collar at the distal tip
Check the handle for chipping or cracking
Oops!
Okay!
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to:
Keep fluid from entering the unit
Test the unit while cleaning
Prevent electrical shock
Keep functioning batteries and cords clean
Oops!
Okay!
Powered surgical instruments have one of three power sources: electric, compressed gas (pneumatic) or battery.
False
True
Oops!
Okay!
The purpose of the insulation covering laparoscopic instruments is to:
Protect the surgeon from burns
Help keep the instrument from slipping during surgery
Protect the patient from electrical current
Protect the patient from cauterization
Oops!
Okay!
Endoscopes are often processed in a mechanical unit called
a flush-pulse endoscope reprocesser
an ultrasonic cleaner
an automatic endoscope reprocessor
a washer-decontaminator
Oops!
Okay!
Used in ear surgery and for driving very small wires through bone
sternal saw
dental drill
micro drill
dermatome/dermabrader
Oops!
Okay!
Leak testing should be performed on each flexible endoscope on an annual basis.
True
False
Oops!
Okay!
All powered surgical instruments should be lubricated each time they are processed.
True
False
Oops!
Okay!
Flexible endoscopes that fail a leak test may continue to be used until the break/hole impacts the scope's function.
False
True
Oops!
Okay!
All flexible endoscopes have internal channels.
True
False
Oops!
Okay!
Accessories for electric-powered equipment includes:
Hoses
Pressure regulators
Decontamination hoses
Foot switches
Oops!
Okay!
Endoscope channels should be cleaned and then left moist for storage.
True
False
Oops!
Okay!
Which of the following should be used to rinse (remove) detergent from a rigid endoscope's channels?
Treated water
Forced air
Water containing an approved sterilant
Water quality per the manufacturer's (IFU)
Oops!
Okay!
An arthroscope is an example of a pneumatic device.
True
False
Oops!
Okay!
Laparoscopic instrument insulation failure can cause burns.
False
True
Oops!
Okay!
Loaned instruments should:
Be sterilized using a low-temperature process
Not be used
Be decontaminated if they appear soiled upon arrival
Be decontaminated before use
Oops!
Okay!
One of the main reasons for powered surgical instrument repair is:
Lack of preventative maintenance (PM)
Poor sterilization practices
Improper storage
Kinking of the umbilical cable
Oops!
Okay!
Used to harvest skin grafts and reshape skin surfaces
dental drill
dermatome/dermabrader
cebatome
sternal saw
Oops!
Okay!
Used to perform specific cutting actions
dermatome/dermabrader
dental drill
sternal saw
saw
Oops!
Okay!
Robotic instruments:
All Choices
Mechanical/electrical components on end of the instrument
Do not come apart for cleaning
Are heavier than standard laparoscopic instruments
Oops!
Okay!