  • Dark areas on the lens of an endoscope are:
    Damaged light fibers
    Light-emitting diode (LED) optics
    Debris
    LED bulbs
  •  15
  • Electronic testing of laparoscopic insulation should be done:
    In the Operating Room (OR) at the end of the procedure
    In the clean assembly area prior to set assembly
    In the decontamination area prior to cleaning
    At the factory or onsite repair unit
  •  15
  • Which of the following should be used to rinse (remove) detergent from a rigid endoscope's channels?
    Water containing an approved sterilant
    Water quality per the manufacturer's (IFU)
    Forced air
    Treated water
  •  15
  • Arthroscopy instruments are used during:
    Laparoscopic surgery
    Robotic surgery
    All the above
    Joint surgery
  •  15
  • Robotic instruments:
    Are heavier than standard laparoscopic instruments
    All Choices
    Mechanical/electrical components on end of the instrument
    Do not come apart for cleaning
  •  15
  • Which of the following statements about endoscopes is true?
    All endoscopes should be steam sterilized
    Ultrasonic cleaning is the process of choice for endoscopes
    Flexible endoscopes are time-consuming to clean
    Flexible endoscopes are not easily damaged
  •  15
  • Which of the following steps occurs first when processing flexible endoscopes?
    Leak testing
    Manual cleaning
    High-level disinfection/sterilization
    Drying
  •  15
  • The first step when inspecting the insulation of a laparoscopic instrument is to:
    Visually check the instrument's shaft
    Check the handle for chipping or cracking
    Check the metal collar at the distal tip
    Try to slide the insulation back
  •  15
  • Loaned instruments should:
    Be decontaminated if they appear soiled upon arrival
    Be sterilized using a low-temperature process
    Not be used
    Be decontaminated before use
  •  15
  • The purpose of the insulation covering laparoscopic instruments is to:
    Protect the patient from cauterization
    Help keep the instrument from slipping during surgery
    Protect the surgeon from burns
    Protect the patient from electrical current
  •  15
  • The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to:
    Test the unit while cleaning
    Prevent electrical shock
    Keep functioning batteries and cords clean
    Keep fluid from entering the unit
  •  15
  • Robotic instruments:
    May have exposed cables
    Are processed the same as laparoscopic instruments
    Must be containerized for sterilization
    Require extensive preventive maintenance (PM)
  •  15
  • Which of the following is an advantage of minimally invasive surgery (MIS)?
    All procedures can be done in a same-day surgery center
    Fewer instruments are used
    Cost savings for the patient
    Shorter recovery times
  •  15
  • Which of the following statements about endoscopes is true?
    Flexible endoscopes are not easily damaged
    Flexible endoscopes are time-consuming to clean
    All endoscopes should be steam sterilized
    Ultrasonic cleaning is the process of choice for endoscopes
  •  15
  • Accessories for electric-powered equipment includes:
    Foot switches
    Decontamination hoses
    Pressure regulators
    Hoses
  •  15
  • Powered surgical instrument attachments:
    Should be sterilized while still attached to the handpiece
    Can all be mechanically cleaned
    Are interchangeable with all types of drills
    Can be peel packaged for if approved by the manufacturer
  •  15