  • What type of connector does one end of the extension cable have to connect to the probe
    75-ohm miniature coaxial female connector
    USB connector
    100-ohm twisted pair connector
    50-ohm BNC connector
  • What type of connector is found on the other end of the extension cable to connect to the proximitor
    75-ohm miniature male connector
    25-pin D-sub connector
    Standard RCA connector
    75-ohm miniature female connector
  • What does the proximitor contain in a proximity transducer system
    The system electronics
    The vibration rack
    The probe tip assembly
    The shaft and bearings
  • What does the tip assembly of the probe contain
    A stainless-steel rod
    A frequency generator
    A coil terminated with a 75-ohm miniature tri-axial cable
    A lubrication nozzle
  • What is the primary function of a transducer’s performance curve?
    b. to set the gap on the probe
    a. to calibrate the proximitor
    d. to be useful as a maintenance record
    c. to reveal the transducer’s scale factor and linear range
  • What is the scale factor shown in the performance curve?
    20 mv/mil
    20 volt/mil
    200 volt/mil
    200 mv/mil
  • Where is the proximitor normally mounted in a continuously monitoring system
    In a junction box
    Next to the lubrication system
    Inside the probe casing
    On the machine shaft
  • Which type of transducer measures and converts shaft vibration
    Accelerometer
    Phase angle meter
    Proximity device
    Seismic device
  • What are the two basic methods of equipment protection monitoring
    Electrical and mechanical
    Continuous and periodic
    Internal and external
    Automatic and manual
  • Which component in the monitoring system controls system resets
    Transducer
    Power supply
    System monitor
    Field wiring
  • How many monitors and their transducers can the power supply provide regulated power to
    20
    8
    4
    12
  • In a vibration monitoring system, which component provides the link between the transducer and the monitoring system?
    Probe
    Field wiring
    Junction box
    Alarm circuit
  • What is the function of the power supply in a monitoring system rack
    To reduce machine noise
    To align the shaft and bearings
    To provide regulated power to monitors and transducers
    To convert vibration into electronic signals
  • Which of the following can be included in a monitoring rack
    Voltage, current, power factor
    Lubrication pressure, fuel level, shaft diameter
    Alignment, balance, belt tightness
    Acceleration, velocity, dual temperature
  • What occurs when probe does not have enough side clearance around the tip?
    c. side view occurs
    b. crosstalk occurs
    d. voltage drops
    a. linear range occurs
  • Where are permanent monitoring systems normally mounted
    Inside the motor casing
    On the shaft directly
    In racks
    In the bearing housing
  • When do crosstalk problems occur?
    when the dc voltage supply is too low
    when two probes are mounted too close together
    when the system components are mismatched
    when a probe is mounted in an area with not enough side
  • What is the main function of a transducer in a vibration monitoring system
    To lubricate the bearings
    To balance the shaft
    To reduce machine speed
    To measure and convert vibration into electronic signals
  • Which of the following voltages can the power supply convert into the DC voltages used by monitors and transducers?
    115 Vac, 220 Vac, +20 to +34 Vdc, +90 to +140 Vdc
    50 Hz and 60 Hz AC
    24 Vac and 48 Vac
    +5 Vdc and +12 Vdc only
  • Which of the following are the three basic parts of a monitoring system rack
    Power supply, system monitor, vibration and thrust monitors
    Shaft, bearings, and coupling
    Alarm system, shutdown system, and data acquisition system
    Probe, extension cable, and proximitor
  • Which of the following are the main components of a continuous monitoring system
    Motor, pump, turbine
    Shaft, bearings, coupling
    Transducer, field wiring, monitoring system
    Probe, proximitor, junction box
  • Where is the proximity probe installed
    On the machine you want to monitor
    On the proximitor
    In the vibration rack
    Inside the extension cable
  • What is the function of field wiring in a continuous monitoring system
    To measure casing vibration
    To reduce shaft misalignment
    To power the motor
    To connect the monitoring system to the transducer
  • What is the function of the extension cable in a proximity transducer system
    To generate the RF signal
    To measure shaft displacement directly
    To connect the probe to a convenient junction box
    To reduce machine vibration
  • What supply voltages can be selected for transducers in a monitoring system
    -24 Vdc or -18 Vdc
    +12 Vdc or +15 Vdc
    +24 Vdc or +18 Vdc
    -12 Vdc or -5 Vdc
  • What angle is used when installing Vibration probes
    c. 90° from the vertical
    b. 25° from the horizontal
    d. 70° from the vertical
    a. 45° from the vertical
  • What are the three main components of a proximity transducer system
    Probe, lubricator, and vibration meter
    Probe, shaft, and rotor
    Probe, extension cable, and proximitor
    Probe, bearing, and motor
  • Why do most monitoring systems use two probes installed 90° apart
    To detect shaft movement in all directions
    To increase shaft speed
    To reduce electromagnetic field strength
    To balance the shaft load
  • What occurs when RF fields of probes are interact with each other?
    voltage drops
    side view occurs
    linear range occurs
    crosstalk occurs
  • What is the reading on the micrometer shown?
    c. 165 mils
    b. 245 mils
    d. 265 mils
    a. 255 mils
  • What does the continuous monitoring method do
    Monitors equipment data at regular intervals
    Monitors equipment constantly
    Checks equipment only after shutdown
    Uses only portable instruments
  • How does the periodic monitoring method collect data
    By checking lubrication levels
    By using portable instruments at regular intervals
    by using permanently installed sensors
    By observing equipment visually
  • Which parameter is not typically monitored by parameter-specific monitors
    Dual thrust
    Speed of rotation
    Dual vibration
    Shaft alignment
  • What do parameter-specific monitors in a monitoring system provide
    Power supply voltages
    Lubrication levels of the bearings
    Alignment of the shaft
    Views of the condition of the machinery
  • What is the reading on the micrometer shown?
    b. 217 mils
    d. 242 mils
    c. 238 mils
    a. 213 mils
  • Which of the following is one function of the system monitor
    To align the shaft and bearings
    To generate RF signals for the probe
    To check the voltage supplies
    To convert vibration into electronic signals
  • When do side view problems occur?
    the system components are mismatched
    a probe is mounted in an area with not enough side clearance
    the dc voltage supply is too low
    two probes are mounted too close together
  • Which of the following is one function of monitors in the system rack
    To generate RF signals for the probe
    To connect probes to the proximitor
    To provide regulated power to the rack
    To show that the transducer system is operating properly
  • What does the system monitor control in the monitoring system
    Shaft speed and lubrication
    The system’s OK relay, resets, and alarm settings
    The proximity probe electromagnetic field
    The field wiring connections
  • What is the un-reliable reading Gap section shown in the performance curve?
    0 to 10 mils
    25 to 75 mils
    0 to 20 mils
    35 to 95 mils
  • What is the function of the monitoring system in a vibration monitoring setup
  • How are probes typically positioned in monitoring systems to measure shaft movement in all directions
    Opposite each other at 180°
    Side by side at 0°
    Installed 90° apart
    Placed randomly around the shaft
  • Which type of transducer measures and converts casing vibration
    RMS device
    Frequency probe
    Seismic device
    Proximity device
  • How does the system monitor support data collection and manipulation
    By monitoring belt tension
    By storing lubrication records
    By regulating shaft vibration
    By providing a communication link