15
×
Which of the following should be used to thoroughly rinse all traces of detergent from a rigid endoscope's channels?
Treated water
Water quality recommended in the manufacturerโs instructions for use
Forced air
Water containing an approved sterilant
Oops!
Show
Check
Okay!
Check
15
×
Which of the following statements about endoscopes is true?
Ultrasonic cleaning is the process of choice for endoscopes
Flexible endoscopes are time-consuming to clean
Flexible endoscopes are not easily damaged
All endoscopes should be steam sterilized
Oops!
Show
Check
Okay!
Check
15
×
Arthroscopy instruments are used during:
Joint surgery
All choices
Laparoscopic surgery
Robotic surgery
Oops!
Show
Check
Okay!
Check
×
seesaw
Swap points!
Oops!
×
star
Double points!
Okay!
×
rocket
Go to first place!
Okay!
×
thief
Give points!
5
10
15
20
25
15
×
Robotic instruments:
Do not come apart for cleaning
Are heavier than standard laparoscopic instruments
All choices
Have mechanical & electrical components in the end of the instrument
Oops!
Show
Check
Okay!
Check
15
×
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to:
Keep functioning batteries and cords clean
Keep fluid from entering the unit
Test the unit while cleaning
Prevent electrical shock
Oops!
Show
Check
Okay!
Check
×
baam
Lose 15 points!
Oops!
×
star
Double points!
Okay!
×
shark
Other team loses 20 points!
Okay!
×
banana
Go to last place!
Oops!
15
×
Loaned instruments should:
Be decontaminated before use
Not be used
Be sterilized using a low-temperature process
Be decontaminated if they appear soiled upon arrival
Oops!
Show
Check
Okay!
Check
15
×
Dark areas on the lens of an endoscope are:
Damaged light fibers
LED bulbs
Debris
Light-emitting diode optics
Oops!
Show
Check
Okay!
Check
15
×
Electronic testing of laparoscopic insulation should be done:
In the decontamination area prior to cleaning
In the clean assembly area prior to set assembly
At the factory or onsite repair unit
In the Operating Room at the end of the procedure
Oops!
Show
Check
Okay!
Check
15
×
The purpose of the insulation covering laparoscopic instruments is to:
Help keep the instrument from slipping during surgery
Protect the patient from cauterization
Protect the patient from electrical current
Protect the surgeon from burns
Oops!
Show
Check
Okay!
Check
15
×
Which of the following steps occurs first when processing flexible endoscopes?
Manual cleaning
High-level disinfection/sterilization
Leak testing
Drying
Oops!
Show
Check
Okay!
Check
15
×
The first step when inspecting the insulation of a laparoscopic instrument is to:
Check the handle for chipping or cracking
Visually check the instrumentโs shaft
Check the metal collar at the distal tip
Try to slide the insulation back
Oops!
Show
Check
Okay!
Check
15
×
Robotic instruments:
May have exposed cables
Are processed the same as laparoscopic instruments
Must be containerized for sterilization
Require extensive preventive maintenance
Oops!
Show
Check
Okay!
Check
×